- GI Powder Coated Clean Rooms (GI)
- NANOCORE-60 / NANOCORE-80 / NANOCORE-100
- ULTRACORE-60 / ULTRACORE-80 (Round Corner)
- High Pressure Laminate Clean Rooms (HPL)
- DECOCORE-66 / DECOCORE-86 (Round Corner)
- Glass Reinforced Polymer Clean Rooms (GRP)
- FIBERCORE-150
GMP Clean Room Partitioning System is designed for ease in installation and a practical functionality, while maintaining a modular flexibility to interchange through ease of demountability. Whether you are adding-on, modifying an existing facility, or constructing a new facility, the GMP panel system offers materials to suit your specific application.
The GMP system can be integrated with a wide range of new or existing systems to coordinate any clean room facility or manufacturing environment. Simplified construction methods and our Progressive/ Non-Progressive systems will help our clients minimize overall construction time.
- PPGI
- PRE-PAINTED GI CLEAN ROOM
- GMP Matel Doorsets
- Fire Rated Doors
- Industrial Doors
- Clean Room Doors
- Acoustic Doors
Modular Clean Room
- Specification
- Purity Classes for Sterile Zones
- Service 4
- Service 3
System | 1200mm, 1000mm and 900mm as standard. Panel thickness 60/80/100mm. Ability to carry |
Height | Upto 6000mm with provision for stacked panels for higher application. |
Base Detail | Recessed adjustable base section to allow a flush coved finish. |
Insulation | Bonded mineral wool or polyisocyanurate foam cores assure absolute panel rigidity. Alternative cores available, such as honeycomb papercore/ aluminium. |
Weight | 9kg/m2 to 25kg/m2 dependent upon specification and thickness. |
Surface Finish | Electrostatically applied epoxy polyester powder coated finish applied in suitable RAL colours. |
Panel Connection | Each panel is connected to its adjacent unit or door unit with a friction-type interlocking key. This allows speedy erection and dismantling. |
Glazing | Double flush glazing with 6mm toughened glass on both sides within a stainless steel framing. |
Doors | Steel construction; optional double and single glazed apertures. |
Acoustics | Solid panel; Rw 41 dB – (BS 5821) |
Coving | Optional radiused floor/ceiling coving accessories. |
Air Leakage | Silicone for sealed applications. |
Clean Rooms are designed to provide this by meeting purity classes based on ISO and DIN standards, as appropriate to a given application.
Air particle count | Maximum allowable particle count per m3 | ||||||
DIN EN ISO 14644-1a) | US Federal Standard 209 Sia) | >=0.1 µm | >=0.2 µm | >=0.3 µm | >=0.5 µm | >=1.0 µm | >=5.0 µm |
ISO Class 1 | – | 10 | 2 | – | – | – | – |
ISO Class 2 | – | 100 | 24 | 10 | 4 | – | – |
ISO Class 3 | M1.5 (1)b) | 1000 1240 |
237 265 |
102 106 |
35 35 |
8 | – |
ISO Class 4 | M2.5 (10)b) | 10000 12400 |
2370 2650 |
1020 1060 |
352 353 |
83 | – |
ISO Class 5 | M3.5 (100)b) | 100000 | 23700 26500 |
10200 10600 |
3520 3530 3500 |
832 | 29 0 |
ISO Class 6 | M4.5 (1000)b) | 1000000 | 237000 | 102000 | 35200 35300 |
8320 | 293 247 |
ISO Class 7 | M5.5 (10000)b) | – | – | – | 352000 353000 350000 |
83200 | 2930 2470 2000 |
ISO Class 8 | M6.5 (100000)b) | – | – | – | 3520000 3530000 3500000 |
832000 | 29300 24700 20000 |
ISO Class 9 | – | – | – | – | 3500000 | 8320000 | 293000 |
Galvanized Iron Clean Room
GMP monoblock/modular solid partitioning walls of Galvanized Iron Clean Room are manufactured by use of nominal steel sheets that are hot dipped galvanized.
Glass Reinforced Polymer Clean Room
A complete range of partitions walls and ceiling systems are available to meet the technical specifications of controlled environment rooms.
HPL Clean Room
GMP has developed the HPL clean room walls/Systems for use in high purity classes of clean room requirements based on ISO and GMP standards.